Free Download Distek Evolution 4300 Manual Programs Running

The Distek Eclipse 5300 Automated Dissolution Sampler offers rapid, accurate sampling using precision syringe pumps. The elimination of valves and rotary pumps along with the optimized sample pathway with a minimal 4.5 mL internal volume increases reliability while reducing common sources of sample carryover. Adding a lower-cost ‘child’ sampler is a cost-effective way to sample from two baths. Each of the baths may run the same method or two different independent ones. The integrated optional filter changer enables the use of most common 25 mm syringe filters instead of requiring custom filter plates and also additional bench space.

Home; Blog; Shop; Contact. Xara Widget Pack 1 Rapidshare Free Download Programs. Free Download Distek Evolution 4300 Manual Programs.

Free Download Distek Evolution 4300 Manual Programs Running

• RAPID / ACCURATE SAMPLING - Precision syringe pumps and reduced sample pathway allows for rapid time point high precision collection, as short as 3 minutes or less. How To Install Cgi Proxy Browser. Unique fluid handling closely mimics manual sampling. • NO VALVES OR ROTARY PUMPS - The elimination of valves and rotary pumps along with the optimized sample pathway with a minimal internal volume of 4.5 mL increases reliability while eliminating and reducing common sources of sample carryover. • FILTER CHANGER - The optional, integrated filter changer uses readily available 25 mm syringe filters without the need for custom filter plates or additional bench space. • COLOR TOUCH SCREEN DISPLAY - The icon driven user interface lowers overall cost by reducing training time and user errors while maximizing productivity and command of the autosampler.

When connecting a Distek dissolution system to the Evolution 4300 syringe-pump dissolution autosampler, you will need to connect an RS-485 cable between the two systems to allow for electronic control of the dissolution unit from the autosampler. Depending on the type of dissolution system that is being utilized with the Evolution 4300 autosampler, the specific RS-485 cable needed will be different (the connecting ends are different). If you have our new symphony 7100 or Model 2500, you will need part number 2700-0162 (RS-485 Cable for 4300 Sampler to 7100 and 2500). If you are using an Evolution 6100, Evolution 6300 or 2100C, you will need part number 2400-0004 (RS-485 Cable for 4300 Sampler to 2100C, 6100, and 6300). The Evolution Dissolution System comes standard with a data access key referred to as the produKEY. This key allows methods to be easily copied and transferred to multiple units without having to reprogram the method settings, saving time, and improving your laboratory’s efficiency.

There is also a calibration produKEY to store and easily retrieve calibration data in case of a failure. Additional produKEYs are available from Distek. Each produKEY is capable of storing up to five methods. Saving a Method to the produKEY: Note: The operator logged in to the system must be part of the Manager group to save a method to the produKEY.

Insert the produKEY into the slot to the right of the control keypad. Turn the key clockwise ¼ turn. The unit will produce an audible beep. Return to the Main screen. Open the method to be saved to the produKEY: From the Main screen select the Auto Mode Wizard (see Figure 1). One of the core features of the Evolution 6100 that differentiates it from the competition is the ability to run different temperatures in each position simultaneously. In addition the media volume and stirring element can also be varied for each vessel.

The ability to vary key parameters like temperature is important in formulations and R&D. During development n=6 testing is typically not required; therefore the 6100 allows users to increase their throughput by testing their formulations at different temperatures simultaneously on the same unit.

While you may already be aware of this capability, you may be unsure how to program the system to run such parameters. Below you will find a step by step guide for setting individual temperatures in each position of the Evolution 6100. Controlling Vessel Temperature Individually on the 6100 1- From the main screen select the MANUAL MODE wizard button.